6
Way Automatic Heat Treatment Console - PCR2007-6 |
|
|
Standard Features are:
75 KVA (3 phase) isolated copper wound power transformer: Primary
Voltage: 380/415/440/480/575, 50/60 Hz Secondary Voltage 65/85 with
thermal trips per phase to prevent overload.
• Internal 12 Channel Chino Digital Recorder (Simultaneous Display/12
Channels/°C or °F) 180mm/7" Chart (model AH3725-N00)
• Automatic programmer FGHP256 (°C or °F) controls temperature
rate of rise, length of hold time and rate of cool. Also has reversed
thermocouple feature. User friendly and simple operation
• Digital amp meter (0-200 amps) with six-channel selector switch
and six current transformers which is the utmost importance for checking
the current to the ceramic pad heater to make sure they are all operating.
• Stainless steel cabinet with swivel wheels (900 lb capacity
each with brake) and two lifting lugs. **Wheels or SS mounting brackets
available upon request.
• One 420 CFM cooling fan which keeps all instrumentation and
transformer cool.
• One 110 volt auxiliary plug.
• 100 amp - 3 phase circuit breaker with 120 volt uv release.
• Six 200 amp ALBRIGHT contactors.
• Six 110 volt neons and six two way on off on switches.
• Instrument wiring tinned copper to prevent corrosion and down
time |
|