email: info@maritimestress.com
ProductsServicesDownloadsContactcompany_profile

Home > Product Categories > Heat Treatment Consoles > PB2010-6

Automatic Heat Treatment Console: PB2010-6 Go To Your Shopping Basket


Qty:

SPEC_SHEET

Standard Features are:
  • 75 KVA (3 phase) isolated copper wound power transformer: Primary Voltage: 380/415/440/480/575, 50/60 Hz Secondary Voltage 65/85 with thermal trips per phase to prevent overload.
  • Automatic programmer FGHP256 (°C or °F) controls temperature rate of rise, length of hold time and rate of cool. User friendly and simple operation
  • Digital amp meter (0-200 amps) with six-channel selector switch and six current transformers.
  • Stainless steel (900 lb capacity each with brake) and two lifting lugs. **Wheels or SS mounting brackets available upon request.
  • One 420 CFM cooling fan.
  • One 110 volt auxiliary plug.
  • 100 amp - 3 phase circuit breaker with 120 volt uv release.
  • Six 200 amp ALBRIGHT contactors.
  • Six 110 volt neons and six two way on off on switches.
  • Instrument wiring tinned copper to prevent corrosion and down time.

 

 


2005 © Maritime Stress - Site Design and Hosted By Eastwood Design