Home > Product
Categories > Heat Treatment
Consoles > P2003-6-NC

6
Way Automatic Heat Treatment Console - P2003-NC  |
| 
|
|
Standard Features are:
• 75 KVA (3 phase) isolated copper wound power transformer: Primary Voltage:
380/415/440/480/575, 50/60 Hz Secondary Voltage 65/85 with thermal trips per
phase to prevent overload.
• Internal 12 Channel Chino Digital Recorder (Simultaneous Display/12 Channels/°C
or °F) 180mm/7" Chart (model AH3725-N00)
• Automatic programmer FGHP256 (°C or °F) controls temperature rate
of rise, length of hold time and rate of cool. User friendly and simple
operation
• Digital amp meter (0-200 amps) with six-channel selector switch and six
current transformers which is the utmost importance for checking the current
to the ceramic pad heater to make sure they are all operating.
• Painted steel cabinet with swivel wheels (900 lb capacity each with brake)
and two lifting lugs. **Wheels or SS mounting brackets available upon request.
• One 340 CFM cooling fan which keeps all instrumentation and transformer
cool.
• One 110 volt auxiliary plug.
• 100 amp - 3 phase circuit breaker with 120 volt uv release.
• Six 200 amp contactors.
• Six 110 volt neons and six two way on off on switches.
• Instrument wiring tinned copper to prevent corrosion and down time |
|