Home > Product
Categories > Heat Treatment
Consoles > B2002-6

Basic Heat
Treatment Console: B2002-6 |
| 
|
|
Standard
Features are:
- 75 KVA (3 phase) isolated copper
wound power transformer: Primary Voltage: 380/415/440/480/575,
50/60 Hz Secondary Voltage 65/85 with thermal trips per phase
to prevent overload.
- Six digital temperature controllers (°C or °F) with
ramp rate in degrees/hr to set point and capable of performing
up to six different processes at a time. (1/8 DIN)
- Digital amp meter (0-200 amps) with six-channel selector switch
and six current transformers.
- Painted steel cabinet with swivel wheels (900 lb capacity
each with brake) and two lifting lugs. **Wheels or SS mounting
brackets available upon request.
- One 340 CFM cooling fan.
- One 110 volt auxiliary plug.
- 100 amp - 3 phase circuit breaker with 120 volt uv release.
- Six 200 amp contactors.
- Six energy regulators with aluminum knobs and scales.
- Six 110 volt neons and six two way on off on switches.
- Instrument wiring tinned copper to prevent corrosion and down
time.
|
|